The
Electrolizing Corporation of Ohio utilizes a variety of highly
sophisticated equipment to assure the precision of our micro-plating
and coating. Metal finishing for micromachined parts depends
on the ability to analyze and inspect finish quality on subminiature
levels. The same technology that allows this advanced capability
also supports the development of new and better finishes and
process techniques.
A combination of microscopic, X-ray, atomic
analysis and optical inspection equipment enables the highest
quality finishing of exceptionally small parts. The Electrolizing
Corporation of Ohio is fully equipped to provide superior quality
control of all finishing procedures.
NIKON
MICROSCOPE
With
a magnification of up to 260X, this powerful microscope gives Electrolizing
the capability of visually analyzing the precision of plating and coating
on even the smallest parts. In many cases, these are so small that
unassisted visual inspection of the part itself is difficult, if not
impossible. Plating thicknesses on surfaces measured in ten-thousandths
of an inch must be precise and even. This Nikon microscope brings these
micro-miniature elements into view with exceptional clarity. Inspection
on a microscopic level also exposes imperfections or process faults
that can then be adjusted to insure the optimum quality of the plating.
Specifications
• Nikon
Microscope
• Magnification: up to 260X
• Fully on-line integrated with real-time send capabilities
• Optical and digital images
• Computer controlled camera
• Download to e-mail or disk
X-RAY
EQUIPMENT
CMI-950
Fluorescence Measurement System
Providing
both optical and digital analysis with X-Ray Radio Frequency, this
device offers the most accurate method of determining plating thickness
other than destructive testing. The spectrographic capabilities of
the X-Ray Fluorescence Measurement System also allow the composition
analysis of the part and its plating. This equipment is used extensively
in the plating of micromachined medical, nuclear, telecommunications,
data communications and fiber optic components. And job costs impacted
by precious metal plating especially benefit from the ability to
determine precise plating dimensions. The accuracy of this technology
allows exceptional process control and inspection capabilities on
all plating methods with the exception of anodizing.
|
|
Specifications
- CMI-950
X-Ray Fluorescence Measurement System
- X-Ray Radio Frequency provides optical and digital images
- Color camera – up to 30X magnification
- CMI’s SmartLink™, FP Windows™ - based operating system
- Programmable Tri-Axis control package
- Maximum part height: 5.90”
- Accuracy: ± .000005”
- Thickness measurement range: .000005 - .001”
- Range: .0002 - .0005”
ATOMIC ABSORPTION UNIT
Perkin
Elmer Analyst 300 Unit
Our
Atomic Absorption Unit (AAU) is a superior analytical tool that provides
a number of capabilities for process development, regulatory compliance
and plating quality. This complex equipment provides a finite solution
analysis of precipitated metals. By detecting metals in a solution,
a chemical or metallurgical engineer can analyze and adjust plating
constituents. Immediate modifications can be made, reducing response
time and increasing project efficiency. In addition, the AAU is invaluable
in the preventive maintenance of solutions, an important consideration
in the management of time, cost and quality. The AAU allows significant
opportunities for developing proprietary solutions in direct response
to customer needs. In addition, the AAU puts Electrolizing on the cutting
edge of regulatory compliance by providing unsurpassed solution analysis and correction
capabilities.
Specifications
• Perkin
Elmer Analyst 300 Unit
• WinLab Controller Program with Windows™ operating
system
•
Automatic 6-lamp turret
• Analyze the following elements in solution to .5 ppm:
• Pb (Lead) • Cr (Chrome • Fe
(Iron)
•
Cd (Cadmium) • P (Phosphorus)
•
Ag (Silver) • Cu (Copper)
•
Ni (Nickel) • Zn (Zinc)
•
Ba (Barium) • Trivalent Chrome
•
Sulfates and Chlorides in aqueous solutions
ADDITIONAL
QUALITY CONTROL/ANALYSIS EQUIPMENT
The Electrolizing Corporation of Ohio employs a high number of inspection-to-production
personnel to insure the quality of our finishing. Our technicians and engineers
have the expertise to maximize the capabilities of our inspection equipment.
The technology provided by microscopic, X-Ray and molecular analysis is complemented
by a variety of modern, conventional inspection options.
Additional
Equipment/Capabilities
• CMI
XRX X-Ray System for Nuclear Applications
• Fischer Eddy current thickness gages
• Nikon V-12-B optical comparator
• Mitutoyu 0-1 digital micrometers
• Full complement of micrometers/bore gages to 16” diameter,
ID and OD
|